Keyence GT-A22L Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Capteurs Keyence GT-A22L. KEYENCE GT-A22L User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 2
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
1
GT Series - Digital Contact Sensors
Sensor Head (Air Push Models)
Supplemental Manual
Read this manual before using.
After reading this manual, keep it in a safe place for quick reference.
Safety Precautions
z
Cylinder
This product uses a single-acting cylinder. The internal spring will
return the cylinder to its home position when air pressure is
removed. DO NOT supply air to the exhaust valve.
The cylinder is an integral part of the sensor. It cannot be removed.
z
Air
To ensure repeatable results, maintain regulated pressure to the air
cylinder.
Use of air cylinders, mist separators, dryers will ensure maximum
operating life.
z
Duct Assembly
The coupling socket and exhaust valve are integrated into the
sensor housing. They cannot be removed.
Names of Sensor Head Parts
Air Tube
The following tubing is recommended for all GT air push models:
How to Attach/Detach the Air Tube
z
Attaching the air tube
Feed the tubing into the socket until it bottoms out (about 1/2").
The socket will ensure a tight seal around the tubing.
•For best results, cut the end of the tube at a right
angle, ensure that the outer perimeter is not
damaged, and that it still maintains a circular cross
section.
•If the tube is not properly inserted, air leakage may
result (see figure below).
•After attachment, pull on the tube to make sure it is
secure.
z
Detaching the air tube
To detach the air tube, (1) press down on the release ring, (2) pull
out the tube.
•Before detaching the tube, be sure to stop any air
flow.
•Press down on the release ring evenly from both
sides, and pull the tube out. Uneven pressure may
result in damage to the tube or damage to the
operation of the air cylinder.
CAUTION
Connect this product to the GT-70A Series
sensor amplifier before using. Be sure to
carefully read the instruction manual supplied
with the sensor amplifier and that it is fully
understood before using.
Dust boot
Spindle
Contact
Coupling socket
Operation indicator
Exhaust valve
Mounting fixture
Dust boot*
Contact
Air cylinder
Connector
* Not mounted on GT-A10L/A22L.
Item Description
Recommended tubing material Nylon, Urethane
Tubing size
Outer diameter 4 mm
Inner diameter 2.5 mm
Coupling socket
Air tube
Note
Tube end
(2)
(1)
Release ring
Note
96M1757
Vue de la page 0
1 2

Résumé du contenu

Page 1 - Sensor Head (Air Push Models)

1GT Series - Digital Contact SensorsSensor Head (Air Push Models)Supplemental ManualRead this manual before using.After reading this manual, keep it i

Page 2 - Specifications

2IP67 Enclosure RatingTo m a i n t a i n an IP67 enclosure rating for GT-A10/A22, the following must be satisfied:•Firmly connect tubing with 2.5 mm

Modèles reliés GT-A22 | GT-A10L | GT-A10 |

Commentaires sur ces manuels