6
SL-T11R-IM-E
When the installation and wiring of the SL-V and the SL-T11R are completed, the responsible person-
nel must verify operations in accordance with the checklist shown below. The following checklist cov-
ers the minimum requirements for the SL-T11R. The check items required may vary depending on the
machine where the SL-T11R is installed, and the laws, rules, regulations and standards in the country
or region in which the SL-T11R will be used. KEYENCE strongly recommends that other necessary
check items should be added by the responsible personnel for the use of the SL-T11R.
This checklist only lists the items related to the SL-T11R. Make sure refer to the SL-V instruction man-
ual to create a checklist that also covers the cases where the SL-V is combined.
n Inspection after installation
When the installation of the SL-T11R is completed, the responsible personnel must verify the opera-
tion of the SL-T11R in accordance with the checklist shown below.
The checklist below covers the minimum requirements for the SL-T11R. The check items required
may vary depending on the machine installed the SL-T11R and the laws, rules, regulations and stan-
dards in the country or region in which the SL-T11R will be used. KEYENCE strongly recommends
that other necessary check items should be added by the responsible personnel for the use of the
SL-T11R.
(1) Pre-check for installation condition
q The machine to which the SL-T11R is installed can stop when it receives the
FSD output from the SL-T11R.
q The interlock reset mechanism (such as switches) is installed so that the
whole hazardous zone can be checked by the responsible personnel and that
operations of the interlock reset mechanisms are not possible within the haz-
ardous zone.
q The SL-T11R is installed in an enclosure of IP54 or higher.
q The DIN rail is fixed on the control panel (enclosure) with adequate strength to
support the weight of the SL-T11R.
q Space is ensured around the SL-T11R for ventilation or heat release as speci-
fied in this manual.
q The installation of the SL-T11R fulfills the conditions specified in this instruc-
tion manual and the requirements of the laws, rules, regulations and standards
in the country or region in which the SL-T11R is used.
(2) Pre-check for wiring
q To supply power to the SL-T11R, the SL-U2 power supply recommended by
KEYENCE is used, or a different 24 VDC power supply that satisfies the power
supply conditions specified in this instruction manual is used.
q The cable for transmitter (cable insulation of grey) is connected to the cable
connector for transmitter, and the cable for receiver (cable insulation of black)
is connected to the cable connector for receiver.
q The safety-related machine control system is established by using both of the
two safety outputs provided on the SL-T11R.
q The polarity is correct for connection to the power supply.
q Wait input is not connected to the output from the safety components compris-
ing a part of safety-related machine control system.
q Non safety-related outputs are not used as a part of the safety-related control
system.
q Wiring is performed in a manner that complies with the requirements of Clause
9.4.3 in IEC60204-1:2005 in order for the protection against malopeation due
to earth fault.
n Regular (periodical) inspection
Following items must be checked in addition to the items for the daily inspection
every six months or whenever the settings of the equipment are changed.
q
Conductive contamination does not occur due to oil or dust adherence.
q
The response time of the whole machine control system is below the design value
and normal.
q Devices with a finite lifetime such as switches, relays or contactors are still func-
tional.
q
Wiring is correctly performed and no modifications or connection changes are
made that may adversely affect the safety-related system of the equipment.
q
There is no disconnection or loose wires to the connection terminal.
q
The screws on the connection terminal are tightened with the specified torque.
q
The open/close cycle of the FSD is within the lifespan. If needed, replace it by
referring to "Replacing the Relay Board".
n Inspection as needed
In the following cases, perform inspection for all the items.
When the unit is installed for the first time
When the parts and wires relating to this system are replaced or changed
When an abnormal operation is found
WARRANTIES AND DISCLAIMERS:
(1) KEYENCE warrants the Products to be free of defects in materials and workmanship for a period of one (1)
year from the date of shipment. If any models or samples were shown to Buyer, such models or samples were
used merely to illustrate the general type and quality of the Products and not to represent that the Products
would necessarily conform to said models or samples. Any Products found to be defective must be shipped to
KEYENCE with all shipping costs paid by Buyer or offered to KEYENCE for inspection and examination.
Upon examination by KEYENCE, KEYENCE, at its sole option, will refund the purchase price of, or repair or
replace at no charge any Products found to be defective.
This warranty does not apply to any defects resulting from any action of Buyer, including but not limited to
improper installation, improper interfacing, improper repair, unauthorized modification, misapplication and
mishandling, such as exposure to excessive current, heat, coldness, moisture, vibration or outdoors air. Com-
ponents which wear are not warranted.
(2) KEYENCE is pleased to offer suggestions on the use of its various Products. They are only suggestions, and it
is Buyer's responsibility to ascertain the fitness of the Products for Buyer’s intended use. KEYENCE will not
be responsible for any damages that may result from the use of the Products.
(3) The Products and any samples ("Products/Samples") supplied to Buyer are not to be used internally in humans,
for human transportation, as safety devices or fail-safe systems, unless their written specifications state other-
wise.
Should any Products/Samples be used in such a manner or misused in any way, KEYENCE assumes no
responsibility, and additionally Buyer will indemnify KEYENCE and hold KEYENCE harmless from any lia-
bility or damage whatsoever arising out of any misuse of the Products/Samples.
(4) OTHER THAN AS STATED HEREIN, THE PRODUCTS/SAMPLES ARE PROVIDED WITH NO OTHER
WARRANTIES WHATSOEVER. ALL EXPRESS, IMPLIED, AND STATUTORY WARRANTIES,
INCLUDING, WITHOUT LIMITATION, THE WARRANTIES OF MERCHANTABILITY, FITNESS FOR
A PARTICULAR PURPOSE, AND NON-INFRINGEMENT OF PROPRIETARY RIGHTS, ARE
EXPRESSLY DISCLAIMED.
IN NO EVENT SHALL KEYENCE AND ITS A FFILIATED ENTITIES BE LIABLE TO ANY PERSON
OR ENTITY FOR ANY DIRECT, INDIRECT, INCIDENTAL, PUNITIVE, SPECIAL OR CONSEQUEN-
TIAL DAMAGES (INCLUDING, WITHOUT LIMITATION, ANY DAMAGES RESULTING FROM LOSS
OF USE, BUSINESS INTERRUPTION, LOSS OF INFORMATION, LOSS OR INACCURACY OF DATA,
LOSS OF PROFITS, LOSS OF SAVINGS, THE COST OF PROCUREMENT OF SUBSTITUTED GOODS,
SERVICES OR TECHNOLOGIES, OR FOR ANY MATTER ARISING OUT OF OR IN CONNECTION
WITH THE USE OR INABILITY TO USE THE PRODUCTS, EVEN IF KEYENCE OR ONE OF ITS
AFFILIATED ENTITIES WAS ADVISED OF A POSSIBLE THIRD PARTY’S CLAIM FOR DAMAGES
OR ANY OTHER CLAIM AGAINST BUYER. In some jurisdictions, some of the foregoing warranty dis-
claimers or damage limitations may not apply.
BUYER'S TRANSFER OBLIGATIONS:
If the Products/Samples purchased by Buyer are to be resold or delivered to a third party, Buyer must provide
such third party with a copy of this document, all specifications, manuals, catalogs, leaflets and written informa-
tion provided to Buyer pertaining to the Products/Samples.
Checklist
00294E 0109-2 96M00294
2008
Document Control No. 922-CA-E002-04
Vue de la page 5
1 2 3 4 5 6

Commentaires sur ces manuels

Pas de commentaire