Keyence CZ-V22A(P) Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Capteurs Keyence CZ-V22A(P). KEYENCE CZ-V22A(P) User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 10
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
1
E CZ-V21A(P)/V22A(P)-IM
RGB Digital Fiberoptic Sensor
CZ-V21A(P)/V22A(P)
Instruction Manual
BE SURE TO READ THESE MESSAGES CAREFULLY
ACCESSORIES
Amplifier unit
•Mounting bracket: 1 End unit: 2 • Instruction manual: 1
Supplied with the CZ-V21A(P) Supplied with the CZ-V22A(P)
Sensor head
Common:
Mounting bracket: 1 (two types, one of each for the CZ-H72)
Board nut: 1
CZ-H32/H35S/H37 only :
M3 x 20 screw: 2
CZ-H52 only :
M3 x 22 screw: 2
Fiber insertion port cover seal: 1
Ultraviolet ray spot check sheet : 1
CZ-H72 only :
M3 x 30 screw: 2
M3 x 6 screw: 2
PART NAMES
Amplifier unit
Display
* Film calibration indicator when using the CZ-H72
Sensor head
CZ-H32 CZ-H35S/H37S
CZ-H52
CZ-H72
Installing the supplied brackets on the CZ-H72
Install the two supplied brackets by combining them as shown below.
The sensor angle can be adjusted within 90° (± 45°).
(Refer to the lower right of page 9.)
Warning
The CZ-V21(P)/V22(P) is just intended for the detection of target
objects. Do not use the CZ-V21(P)/V22(P) in a safety circuit to pro-
tect the human body.
The CZ-V21(P)/V22(P) does not have an explosion-proof struc-
ture. Do not use it in a location where any flammable gases, liquid
or powder exist.
The CZ-V21(P)/22(P) is a direct current type sensor. Application of
the AC power may lead to burst or fire.
Do not directly look at the emitted LED beam.
The CZ-H32/H35S/H37S/H72 are the Class 1 LED product in which
the light source LED is located in the amplifier unit.
The CZ-H52 is the Class 1M LED product.
*When using the CZ-H52, be sure to read Precaution on Using CZ-
H52 on page 8.
AB
MODE
BANK
1234
SET
C
OUT
1234
AB
MODE
BANK
1234
SET
C
OUT
1234
Fixing lever
Connection
protection cover
MODE button
Connection
connector
SET button
Manual adjustment
button
Output indicator
Display
Dust cover
Receiver connector
port
CZ-V22A(P)
CZ-V21A(P)
AB
BANK
1234
C
Color indicator*
(Lights at C/C+I mode)
Bank indicator
(At C/C+I mode)
Channel indicator
Current value monitor (red)
Setting value monitor (green)
C
Z
-
H
3
2
CZ-H35S
Detection
indicator
Emitter
Receiver
Spot selection switch
Light emission fiber
cable
Light reception
cable
Detection
indicator
Emitter
Receiver
Light emission
fiber cable
Light reception
cable
U
V
O
N
D
E
T
E
C
T
C
Z
-H
5
2
Receiver
Emitter
UV irradiation indicator
(green)
Detection indicator
(red)
Detection indicator
Spot selection switch
Emitter
Receiver
Light emission fiber cable
Light reception cable
96M1382
Vue de la page 0
1 2 3 4 5 6 7 8 9 10

Résumé du contenu

Page 1 - CZ-V21A(P)/V22A(P)

1 E CZ-V21A(P)/V22A(P)-IM RGB Digital Fiberoptic Sensor CZ-V21A(P)/V22A(P) Instruction Manual BE SURE TO READ THESE MESSAGES CAREFULLY ACCESSORIES

Page 2 - MOUNTING THE SENSOR HEAD

10E CZ-V21A(P)/V22A(P)-IMERROR INDICATIONThe following indications on the LCD display show the error events.Correct the problem using the following co

Page 3 - *CZ-V21A only

2 E CZ-V21A(P)/V22A(P)-IM MOUNTING THE AMPLIFIER UNIT CONNECTING SEVERAL AMPLIFIER UNITS Up to three sub-units CZ-V22A(P) can be mounted adjacent to

Page 4 - Press MODE

3 E CZ-V21A(P)/V22A(P)-IM INPUT/OUTPUT CIRCUIT SCHIMATIC Connection diagram DETECTION MODES * For the CZ-H52, the selectable detection mode is “Sup

Page 5

4 E CZ-V21A(P)/V22A(P)-IM OPERATION PROCEDURE FOR USING THE C/C+I MODE Description of indication Matching rate Displays the degree of corresponden

Page 6 - Setting a sensitivity

5 E CZ-V21A(P)/V22A(P)-IM OPERATION PROCEDURE FOR USING THE SUPER I MODE Description of indication Setting a sensitivity 2-point calibration (b

Page 7 - MENU SELECTION

6 E CZ-V21A(P)/V22A(P)-IM OPERATION PROCEDURE FOR USING THE LUSTER DETECTION MODE (CZ-H72) Description of indicationSetting a sensitivity 2-point

Page 8 - EXTERNAL INPUT

7E CZ-V21A(P)/V22A(P)-IMMENU SELECTIONPressing the MODE button for three seconds or more displays the menu, from which each mode can be configured.To e

Page 9 - SPECIFICATIONS

8E CZ-V21A(P)/V22A(P)-IMOTHER FUNCTIONS Power saving functionIf the Eco mode is turned on, three minutes’ absence of operation brings the sensor to t

Page 10 - KEYENCE CORPORATION

9E CZ-V21A(P)/V22A(P)-IMSPECIFICATIONS Sensor head*1 Reference distanceSmall: 65 mm, medium: 60 mm, large: 50 mm*2 Large spot: 15 ± 5 mm, small spot

Modèles reliés CZ-V21A(P)

Commentaires sur ces manuels