Operation for initial start-up
1. Turn on the power of the sensor.
2. Double click the [IV-Navigator] icon.
3. Click the [Direct connection] button.
4. Click the [Connect] button.
5. Select the output polarity of the sensor.
6. The sensor setup screen will be displayed.
Basic setting
Starting the Navigator
Click the [Sensor setup] button to proceed to “STEP1”.
Setting the Image Optimization
1. Click the [Trigger Options] button.
2. Select the Trigger type.
[Internal trigger]: The trigger will be input automatically, according
to the trigger interval settings.
[External trigger]: The trigger will be input when an external signal
is input. If necessary, set the trigger delay.
3. Click the [Brightness Adjustment] button.