Keyence Visual KV Series Manuel d'utilisateur Page 339

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 444
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 338
8.3 Installation
KV-300 Series Only
KV-300
KV-10/80
Chapter 8 KV-AN6 Analog I/O Module
1-315
1
8
8.3 Installation
8.3.1 Terminal Nos.
The following signals are assigned to the terminal nos. of the KV-AN6.
KV-AN6
Signals
Note: Voltage output and current output can be used simultaneously.
0
1
2
3
V4
I4
V5
I5
C0
C1
C2
C3
C4
C5
C6
C7
F.G.
D
/
A
A
/
D
Terminal No. Description Assigned signal
0
A/D
Analog input ch. 0
(±10 V, ±5 V, 0 to 20 mA)
Input range is slide-switch
selectable.
1 Analog input ch. 1
2 Analog input ch. 2
3
Analog input ch. 3
V4 D/A Analog voltage
output ch. 4
(±10 V, ±5 V) Input range is
slide-switch selectable.
I4 Analog current
output ch. 4
4 to 20 mA output range
V5 Analog voltage
output ch. 5
(±10 V, ±5 V) Input range is
slide-switch selectable.
I5
Analog current
output ch. 5
4 to 20 mA output range
. Not used NC
C0
C1
C2
C3
C4
C5
C6
C7
F.G.
Analog GND (common)
Frame ground
KVHKA Chap 08.p65 08.3.11, 11:19 AM315
Vue de la page 338
1 2 ... 334 335 336 337 338 339 340 341 342 343 344 ... 443 444

Commentaires sur ces manuels

Pas de commentaire