Thrubeam Type Laser Sensor
IG Series
Instruction manual
Read this instruction manual carefully prior to operating the IG Series CCD Thrubeam
Laser Sensor.
After reading, keep this manual in a safe place so that you can refer to it at any time.
Safety Information for IG series
General precautions
At startup and during operation, be sure to monitor the functions and performance of this
product and confirm normal operation.
We recommend that you take substantial safety measures to avoid any damage in the
event that a problem occurs.
If the product is modified or used in any way other than described in the specifications, its
functions and performance cannot be guaranteed.
Do not use this product for the purpose of protecting the human body.
Do not subject this device to rapid temperature changes, otherwise product failure may
occur.
Safety Precautions on Laser Product
* The classification is based on IEC60825-1 standard following the Laser Notice No. 50 from
FDA (CDRH).
Laser emission stop input
When the laser emission stop input is activated, the laser emission stops by setting the
external input to ON (for 2 ms or more). The laser emission continues to stop while the
external input is ON. When the external input is set to OFF, the laser is emitted within 2 ms.
For details of the discrete outputs or analog output conditions during the laser emission
stop input, refer to the User’s Manual “11. External input”.
Abnormal conditions
Precautions on use
Installation environment
To ensure that it is being safely used, do not install this product in the following locations.
High-humidity, dusty and poorly-ventilated locations.
High-temperature locations where the unit is exposed to direct sunlight.
Locations where there is corrosive gas or combustible gas.
Locations where the unit may be directly subjected to vibration or impact.
Locations where water, oil, or chemicals may splash onto the unit.
Locations where the static electricity tend to be generated.
Influence of dirt
Measurement errors may occur due to dust, water, oil, etc.
Remove such dirt stuck to transmitter and receiver with either an air purge or wipe with a
soft cloth moistened with alcohol for heavy dirt. If the transmitter and receiver get
scratched, measurement errors may occur.
Remove dirt attached to the target with either an air purge or it off.
If dirt is floating within the measurement range, take adequate measures, such as
installing a dust protection cover or air purging.
Anti-noise prevention
When the unit is installed near a noisy source such as a power generator or high-voltage
line, operational errors or product failure may occur. Take adequate measures such as
using a noise filter, arranging cords appropriately, or insulating the amplifier and sensor
head.
Warm up
Wait approximately 10 minutes after power up before using the IG series so as to allow
forthe display value to stabilize upon warm up.
Other Precautions
Power source
Operation errors may occur due to noise superimposed upon the power source. Make
certain to use the direct current stabilized power source which uses an insulation
transformer.
When using a commercially available switching regulator, make sure to properly ground
the frame.
Precautions on UL Certificate
The IG series complies with the following UL and CSA standards. The IG series has
obtained UL and C-UL certificate.
Applicable standardUL508 Industrial Control Equipment
CAN/CSA C22.2 No.14-M05 Industrial Control Equipment
UL File No.E301717
UL category: NRKH, NRKH7
Precautions
The IG series must have its power supplied from a Class 2 power source according to
NFPA70 (NEC: National Electrical Code).
The UL certificate for the IG series is for the sensor head and amplifier used in
combination. The IG series sensor head must be used together with the IG series sensor
amplifier unit exclusively.
Power supply/Control input/Control output shall be connected to a single Class2 source
only.
Use with over current protection device which is rated 30V or more and not more than 1A.
For details of each function, refer to “CCD Thrubeam Laser Sensor IG Series User’s
Manual”.
You can download “CCD Thrubeam Laser Sensor IG Series Users Manual” from
KEYENCE homepage (http://www.keyence.co.jp/).
WARNINGWARNING
Failure to follow these instructions may lead to injury.
CAUTION
Failure to follow these instructions may lead to product damage (product
malfunction, etc.).
Note
This provides additional helpful information to ensure your understanding of
the unit's functions.
Reference
.
This references information that will aid your understanding of the text
descriptions.
WARNINGWARNING
The IG Series is intended for measuring objects. Do not use this product
for the purpose of protecting the human body.
This product is not made with an explosion proof construction. Do not use
it in a location where any flammable gases, liquid, or powder exist.
WARNINGWARNING
This product employs a semiconductor laser for its light source.
Use of controls or adjustments or performance of procedures other than
those specified herein may result in hazardous radiation exposure.
Follow the instructions mentioned in this manual. Otherwise, injury to the
human body (eyes and skin) may result.
Precautions on class 1 laser products
Do not disassemble this product. Laser emission from this product is not
automatically stopped when it is disassembled.
Do not stare into the beam.
Sensor head IG-010/028
Wavelength 660 nm
Output 62 μW
Pulse width 48 μs
FDA(CDRH)Part1040.10* Class 1 Laser Product
IEC60825-1 Class 1 Laser Product
96M11149
WARNINGWARNING
If the following conditions occur, turn off the power immediately. Continuing
to use this product under abnormal conditions may cause product failure.
When water or foreign matter enters the IG Series
When the IG Series is dropped or the case is damaged
When the IG Series produces smoke or an unpleasant smell
WARNINGWARNING
Use with the specified power source and voltage. Otherwise, fire, electric
shock or product failure may result.
Never disassemble or modify this product. Fire or electric shock may result.
CAUTION
Before disconnecting the cables, make sure to turn off the main unit and
devices connected to the main unit. Otherwise, the unit could be
damaged.
Do not turn off the power to the unit while it is being programmed. Some
or all of the set data may be lost.
CCD
Vue de la page 0
1 2 3 4 5 6 7 8 9 10

Résumé du contenu

Page 1 - IG Series

1 Thrubeam Type Laser SensorIG SeriesInstruction manualRead this instruction manual carefully prior to operating the IG Series CCD ThrubeamLa

Page 2 - Mounting the Amplifier

10Copyright (c) 2010 KEYENCE CORPORATION. All rights reserved.11149E 1070-3 96M11149 Printed in Japanz IG-028TransmitterReceiver Specifications Se

Page 3 - Mounting the Sensor Head

2Checking the Package ContentsBefore using the unit, confirm that the parts and equipment listed below are included in thepackage of the model you pur

Page 4 - Connection and Wiring

3 DIN rail mount type, expansion unit (IG-1050)Up to 3 expansion units can be connected to one main unit.1 Remove the expansion protective cover fro

Page 5 - (OP-84338: optional)

4z When mounting the sensor head from the lateral sideMounting from the sensor sideMount using the commercially available screws (IG-010: M3, IG-028:

Page 6 - Optical Axis Alignment

5 Attaching the sensor head cable connector(OP-84338: optional)Cut the sensor head cable to the required length and attach the new connector to use t

Page 7 - Setting Method

6z Sub displayThe sub display switches each time the W/X button is pressed. According to the type ofdisplayed value selected, the sub display identifi

Page 8 -  4. Output method

76 Measure the LOW side defective target and press the [SET] button.The R.V. (internal measurement value) is now registered.After [UGV] blinks on the

Page 9 - Dimensions

8Basic functions 1. Measurement modeSetting the position to measure.z Edge control/Positioning modeWhen the measurement direction [VQR] (top) is sele

Page 10 - Warranty

9Circuit Diagram Sensor headz Output circuitWhen NPN output is selectedWhen PNP output is selectedz Analog output circuitz Input circuitWhen NPN outp