Keyence FS-N10 Series Manuel d'utilisateur Page 61

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 116
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 60
4-3 Detection Settings (Func)
4
Settings for Advanced Functions
4-15
- Digital Fiber Sensor FS-N10 Series User's Manual -
Methods for setting upper and lower limits
The upper and lower limits can be set using one of the 2 methods:
Setting sensitivity using the percentage calibration mode
See "Percentage calibration" (page 4-5).
Sensitivity setting using other calibration modes
Sensitivity is set separately for Hi and Lo.
1
Press to display "Hi" or "Lo".
The "Hi" or "Lo" value, and the current set-
ting values are displayed alternately.
When the [MODE] button is pressed while
the display alternately flashes, the "Hi" or
"Lo" display changes.
If you do nothing for 3 seconds or more,
the received light intensity display is auto-
matically restored.
2
Press the [SET] button to perform sen-
sitivity setting (two-point calibration,
maximum sensitivity setting, or other).
Calibration is complete after the setting
value flashes momentarily, and then stops
(lights up).
Vue de la page 60
1 2 ... 56 57 58 59 60 61 62 63 64 65 66 ... 115 116

Commentaires sur ces manuels

Pas de commentaire