2.4 Instruction Details
1
2
3-71
Chapter 2 Instructions
On-delay circuit
Output relay 0500 turns ON in a specified time after input relay 0000 turns ON.
When input relay 0000 turns OFF, output relay 0500 also turns OFF.
Timing diagram
Coding
Flicker circuit
Output relay 0500 turns ON and OFF repeatedly while input relay 0000 is ON.
Timing diagram
Coding
0000
T000
0500
#00020
T000
OFF
ON
ON
0000
0500
Line No. Instruction Operand
0000 LD 0000
0001 TMR 000 #00020
0002 LD T000
0003 OUT 0500
0000 T001
T000
0500
#00020
T000
#00010
T001
2 sec.
2 sec.
1 sec.
OFF
ON
ON ON
0000
0500
ON
Line No. Instruction Operand
0000 LD 0000
0001 ANB T001
0002 TMR 000 #00020
0003 LD T000
0004 AMR 001 #00010
0005 OUT 0500
2 s
1 s
2 s
1 s
2 s
1 s
2 s
1 s
TMR
KVNKA Chap 02_4aP.p65 08.3.11, 11:58 AM71
Vue de la page 94
1 2 ... 90 91 92 93 94 95 96 97 98 99 100 ... 391 392

Commentaires sur ces manuels

Pas de commentaire