Keyence DL-CL1 Manuel d'utilisateur Page 35

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 72
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 34
3-2 Device Maps
3-7
3
Communicating with the FD-MH series
- CC-Link Compatible Network Unit DL-CL1 User’s Manual (FD-MH) -
Number [n] denotes the first data memory number assigned to the DL-CL1.
*1 See "Entering an External Input into a Sensor Amplifier" (page 3-17).
*2 See "Reading Current Values (Instantaneous Flow Rate) from Sensor Amplifiers" (page 3-18).
*3 See "Reading/Writing Settings or Status of a Sensor Amplifier" (page 3-21).
See "Issuing a Motion Command to a Sensor Amplifier" (page 3-20).
*4 See "Error information list" (page 3-7).
*5 See "Command response list" (page 3-8).
*6
See "Command Parameter List" (page 3-24).
Error information list
Operating
mode
Device no.
(HEX)
Name
Communication
method
Description Reading range
Small-memory mode 2
Monitor mode 1
RWr[n] + 04
Integration
reset input
response
*1
Stores the integration reset input response of
the sensor amplifi er.
The response is output by assigning sensor
amplifi ers (ID 01 to ID 10) to bits 0 - 9.
0: Input OFF
1: Input ON
RWr[n] + 05
Flow rate hold
reset input
response
*1
Stores the fl ow rate hold reset input response
of the sensor amplifi er.
The response is output by assigning sensor
amplifi ers (ID 01 to ID 10) to bits 0 - 9.
0: Input OFF
1: Input ON
RWr[n] + 06 (Not used) - -
RWr[n] + 07
Current value
property
*2
Used for reading the instantaneous fl ow rate
value.
This property is output by assigning IDs (ID
01 to ID 10) to bits 0 - 9.
The output occurs when the instantaneous
ow rate value read from the sensor amplifi er
is nonnumeric: "over" or "invalid."
0: Normal
current value
1: "over" or
"invalid (-----)"
RWr[n]
+08 to 09
(INT32)
Current value:
box 1
*2
Used for reading the instantaneous fl ow rate
value. The instantaneous fl ow rate value of the
sensor amplifi er of the ID number specifi ed
page number (RWw[n] + 08) is output.Data
type: INT32 (LITTLE)
Page 0: ID 01
Page 1: ID 04
Page 2: ID 07
Page 3: ID 10
RWr[n]
+0A to 0B
(INT32)
Current value:
box 2
*2
The instantaneous fl
ow
rate value of the
sensor amplifi er of the ID number specifi ed
page number (RWw[n] + 08) is output.Data
type: INT32 (LITTLE)
Page 0: ID 02
Page 1: ID 05
Page 2: ID 08
Page 3: (Not
used)
RWr[n]
+0C to 0D
(INT32)
Current value:
box 3
*2
The instantaneous fl ow rate value of the
sensor amplifi er of the ID number specifi ed
page number (RWw[n] + 08) is output.
Data type: INT32 (LITTLE)
Page 0: ID 03
Page 1: ID 06
Page 2: ID 09
Page 3: (Not
used)
RWr[n] + 0E
Temperature
hold reset input
response
*1
Stores the temperature hold reset input
response of the sensor amplifi er.
The response is output by assigning sensor
amplifi ers (ID 01 to ID 10) to bits 0 - 9.
0: Input OFF
1: Input ON
RWr[n] + 0F (Not used) - - -
Error Information
(HEX)
*
Description Cause Corrective action
0000 No error - -
0001
0002
0005
Initialization error
Error encountered during
initialization.
Check the number of connected
sensor amplifiers and the
connection to the sensor
amplifiers, and then cycle power.
If the error remain, contact your
nearest sales office.
0003 Model error
There is connected a sensor
amplifier of a model
incompatible with the DL-CL1.
Connect a sensor amplifier of a
compatible model.
Vue de la page 34
1 2 ... 30 31 32 33 34 35 36 37 38 39 40 ... 71 72

Commentaires sur ces manuels

Pas de commentaire