3-1 Overview of DeviceNet Communication
3-3
3
Communicating with the FD-MH series
- DeviceNet Compatible Network Unit DL-DN1 Users Manual (FD-MH) -
The master unit of the DeviceNet system can use the following functions:
* When you use this function through explicit messaging, use a command parameter
of each function assigned for external inputs (1 to 5). For details, refer to
"Command Parameter List for FD-MH Series" (page 3-24).
I/O Communication
The output signal, comparator value, and error status of sensor amplifiers can be
communicated without the need of a ladder program.
By using the IN and OUT areas as handshake signals, the master unit can execute
external inputs to the sensor amplifier or change setting values.
"I/O Communication" (page 3-4)
Explicit Messaging
The master unit can use explicit messaging commands to directly read
/write
parameter values of
sensor amplifiers. All functions that can be executed on sensor
amplifiers are available through explicit messaging.
"Explicit Messaging" (pa ge 3-17)
Overview of Communication Methods
Function of sensor
amplifier
Communication Methods.
I/O Communication
p. 3-4
Explicit Messaging
p. 3-17
Read status
Ye s
Ye s
Read output
Read current value
Execute external input*
Rewrite setting value
Motion command
No
Read current value,
setting, and status
Read data with decimal point
information
Rewrite setting
Lock all