410GBRead this manual before using the system in order toachieve maximum performance.Keep this manual in a safe place for future reference.BCD Output
8Introduction11-1 Before Using the Unit(2) Sensor amplifier connector (for DIN rail mounting type)Use this connector to connect DL-RB1A to the sensor
9Mounting and Connecting the DL-RB1A22Mounting and Connecting the DL-RB1AThis chapter describes how to mount DL-RB1A, connect it to sensor amplifiers
10Mounting and Connecting the DL-RB1A22-1 Connecting the Unit to Sensor AmplifiersThis section describes how to mount DL-RB1A and connect it to sensor
112-1 Connecting the Unit to Sensor AmplifiersMounting and Connecting the DL-RB1A2 Available sensor amplifiers*1 The GT-70A Series, GT-2 Series, IG
12Mounting and Connecting the DL-RB1A22-1 Connecting the Unit to Sensor Amplifiers• When connecting 3 or more models togetherWhen using 2 or more mod
132-1 Connecting the Unit to Sensor AmplifiersMounting and Connecting the DL-RB1A2 Connecting the DL-RB1A to DIN rail mounted sensor amplifiers1 Rem
14Mounting and Connecting the DL-RB1A22-1 Connecting the Unit to Sensor Amplifiers Connecting the DL-RB1A to panel mounted sensor amplifiers1 Connec
Mounting and Connecting the DL-RB1A2152-1Connecting the DL-RB1A to External DevicesI/O ConnectorThis section describes the pin assignments and each si
16Mounting and Connecting the DL-RB1A22-1 Connecting the DL-RB1A to External DevicesPin Nos. 1 to 4: ID No. selection inputSelect the ID number for t
172-1 Connecting the DL-RB1A to External DevicesMounting and Connecting the DL-RB1A2The following special output occurs depending on the sensor ampli
IntroductionThis manual provides an overview of the BCD output unit DL-RB1A and describes the functions and procedures of the unit.Be sure to read thi
18Mounting and Connecting the DL-RB1A22-1 Connecting the DL-RB1A to External Devices Input circuit diagram Input circuit (Pin Nos. 1 to 5)* The ter
192-1 Connecting the DL-RB1A to External DevicesMounting and Connecting the DL-RB1A2Combining and Wiring ConnectorsTo connect the DL-RB1A to external
20Mounting and Connecting the DL-RB1A22-1 Connecting the DL-RB1A to External Devices Precautions when wiring (OP-23139 and OP-42224)Carefully follow
212-1 Connecting the DL-RB1A to External DevicesMounting and Connecting the DL-RB1A2 Dedicated crimping toolYou can use the dedicated crimping tool
22Mounting and Connecting the DL-RB1A22-1 Connecting the DL-RB1A to External Devices4 Press down on the handle of the dedicated crimping tool until t
23Advanced Functions33Advanced FunctionsThis chapter describes the I/O timing for each operation mode and the data processing time.3-1 Data Processin
24Advanced Functions33-1 Data Processing and Operation ModesSensor Amplifier ID Number AssignmentsWhen the sensor amplifier that is connected to DL-RB
253-1 Data Processing and Operation ModesAdvanced Functions3 Large display type sensor amplifiers (GT2-100N/100P)ID:00 ID:01ID:02 ID:03 ID:04ID:05 I
26Advanced Functions33-1 Data Processing and Operation ModesCommunication Unit Data Update TimeAfter the sensor is detected, the DL-RB1A can output d
273-1 Data Processing and Operation ModesAdvanced Functions3Operation ModesThere are three types of operations modes for DL-RB1A: OUT mode, OR mode,
1Safety PrecautionsGeneral Cautions• At startup and during operation, be sure to monitor the functions and performance of the DL-RB1A for proper opera
28Advanced Functions33-1 Data Processing and Operation Modes OR modeThis mode is used when reading BCD output from multiple DL-RB1A units with one e
293-1 Data Processing and Operation ModesAdvanced Functions3 Time chart(1) An external device inputs "ID No. 01" as the ID No. selection.(
30Advanced Functions33-1 Data Processing and Operation Modes TIMER modeEven without the DRQ input from an external device, the sensor amplifier can
31Appendix44AppendixThis appendix describes the specifications and dimensions of DL-RB1A.4-1 Specifications . . . . . . . . . . . . . . . . . . . .
32Appendix44-1 SpecificationsPerformance specificationsThe following table shows the performance specifications for DL-RB1A.* The number of connectabl
33<Header-1>4-1 SpecificationsAppendix4Dimensions When the unit is mounted on a DIN rail When the optional mounting bracket (OP-60412) is use
34Appendix4<Header-1>4-1 SpecificationsMEMO
35IndexIndexThe following index provides a list of terms used in this manual in alphabetical order.AAdvanced setting switches ...
Revision HistoryDate of printing Version Revision contentsJune 2008September 2008July 2009November 2009February 2010June 2010August 2010September 2014
WARRANTIES AND DISCLAIMERS(1) KEYENCE warrants the Products to be free of defects in materials and workmanship for a period of one (1) year from the
2 Installation environmentTo use the DL-RB1A correctly and safely, avoid installing it in the following locations. Failure to do so may cause fire, e
Copyright (c) 2014 KEYENCE CORPORATION. All rights reserved. 189035E 1094-1 410GB Printed in Japan
3ContentsSafety Precautions ... 1General C
4Chapter 4 Appendix4-1 Specifications... 32Performance s
5Introduction11IntroductionThis chapter describes the information you need to know before you start using the DL-RB1A, such as the package contents an
6Introduction11-1 Before Using the UnitChecking the Package ContentsBefore using the DL-RB1A, check that the following items are all included.We have
71-1 Before Using the UnitIntroduction1(1) Advanced setting switchesYou can use different ON/OFF combinations to configure the output settings.• Make