E DL-PD1_IM
Connecting to a panel mounting type sensor amplifier
1 Connect the sensor amplifier to the DL-PD1 using the optional
expansion cable (OP-35361).
2 Detach the sensor amplifier connector (for DIN rail mounting type)
of the DL-PD1 with pliers and mount the attached expansion
connector sticker.
Connecting to a large display type sensor amplifier
1 Connect the sensor amplifier to the DL-PD1 using the optional
expansion cable (OP-35361).
2 Detach the sensor amplifier connector (for DIN rail mounting type)
of the DL-PD1 with pliers and mount the attached expansion
connector sticker.
Set the station address of the DL-PD1 with the rotary switch at the top of the DL-PD1.
The station address set here must be the same as the one set through the configuration
software of the PROFIBUS DP.
The station address of the DL-PD1 cannot be set to 00, 100, or more.
Set the station address before the DL-PD1 is powered on. When the station address is
changed during operations of the DL-PD1, such change is reflected after power has been
restored to the DL-PD1.
Use the following procedure to connect the DL-PD1 to the PROFIBUS.
Usable cable
Use the shielded twisted pair cable, which is compliant with the PROFIBUS specifications.
Wiring the PROFIBUS Connector
For the PROFIBUS connector of the DL-PD1, the D-sub9 pin connector (socket) is used.
Pin arrangement of the connector is as below.
Turn OFF the power before connecting the expansion
cable and connect securely. Diagonal or otherwise
improper insertion may damage the equipment.
Inserting or pulling the cable when the power is turned
ON may damage the equipment.
Turn OFF the power before connecting the expansion
cable and connect securely. Diagonal or otherwise
improper insertion may damage the equipment.
Inserting or pulling the cable when the power is turned
ON may damage the equipment.
Detach the protection sticker
Expansion cable (cable length: 300 mm)
NOTICE
Sensor amplifier connector
(for DIN rail mounting type)
Expansion
connector sticker
Detach the
protection sticker
Detach the
protection
sticker
Expansion cable (cable length:300 mm)
NOTICE
Sensor amplifier connector
(for DIN rail mounting type)
Expansion
connector sticker
Setting the Station Address
Connecting the PROFIBUS
Pin
number
Signal name Description
1–
2–
3 RxD/TxD-P Communication wire B
4 RTS Request to send
5 M5V2 Standard data unit (Station)
6 P5V2 Power supply: Plus (Station)
7–
8 RxD/TxD-N Communication wire A
9–
Station address setting switch
Setting range: 01 to 99
Default value: 11
5
1
2
3
4
9
8
7
6