4-2 Basic Settings and Advanced Settings
4-26
4
Setting Various Functions
IB-E
The hysteresis for the tolerance setting value is set.
If the judgment value (P.V.) fluctuates due to the vibration of the object, etc. and the
judgment output repeats ON/OFF, increasing the hysteresis value stabilizes ON/OFF.
"3-6 Setting the Tolerance Setting Value" (page 3-13)
" 1. Measurement Mode" (page 4-8)
8. Hysteresis
Item Measurement mode Setting range Default value
Hysteresis
% mode 0.00 to 999.99
0.00
Dimension mode 0.000 to 99.999
0.000
Reference
The above is the timing chart when the output mode of judgment output is
Normally Open (default value). ON/OFF is reversed for Normally Closed.
" 4. Output Mode" (page 4-13)
Time
Hysteresis
Hysteresis
Judgment value (P.V.)
HIGH setting value
LOW setting value
ON
OFF
ON
OFF
ON
OFF
HIGH judgment output
GO judgment output
LOW judgment output