Vue de la page 113
5-5 Objects Usable by DL-EP1
5-34
Ethernet Link Object
5
Appendix
- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (FD-MH) -
Reference 2) Control bits list
List of general and additional statuses returned to each service
Bit Name Description
0 Auto-negotiate
OFF: Auto-negotiation is disabled (communication
setting is fixed at 10 Mbps).
ON: Auto-negotiation is enabled (communication setting
is fixed at 100/10 Mbps auto).
1 ForcedDuplex Mode OFF (fixed)
2 to 15 Reserved OFF (fixed)
Error Code
General
Status
Additional
(Extended)
Status
Description
Get_Attributes_All
00H - The service has ended normally.
05H - The designated instance ID does not exist.
Get_Attribute_Single
00H - The service has ended normally.
05H - The designated instance ID does not exist.
14H - The designated attribute ID does not exist.
Set_Attribute_Single
00H - The service has ended normally.
05H - The designated instance ID does not exist.
09H - The written value is invalid.
0CH -
The object cannot execute the requested
service in the current state.
0EH - The designated attribute ID cannot be written.
13H - The length of send data is too short.
14H - The designated attribute ID does not exist.
Others 08H - The designated service is not supported.