3-8
- PROFIBUS DP Compatible Network Unit DL-PD1 User's Manual (IG) -
Executing Communication
3
3-3 Parameterization
Set parameters on the configuration software of PROFIBUS DP.
Set as necessary.
Standard parameter
Parameters specified by PROFIBUS DP/DPV1 standard
Octet Name Description Value
1 Station Status Station status
BIT2-0: reserved
BIT3: Watchdog on
BIT4: Freeze mode request
BIT5: Sync mode request
BIT6: Unlock request
BIT7: Lock request
2 WD_Fact_1 Watchdog element 1 -
3 WD_Fact_2 Watchdog element 2 -
4 TSDR Shortest TSDR time -
5 Ident number (H) Manufacturer code (high byte) 0D
H
6 Ident number (L) Manufacturer code (low byte) FD
H
7 Group ID
Group assignment for broadcast and
multi cast (SYNC,FREEZE, CLEAR)
-
8 DPV1 Status1 DPV1 status 1 (See EN50170.)
BIT1-0: reserved
BIT2: Watchdog time base 1 ms
BIT4-3: reserved
BIT5: 0 (fixed)
BIT6: Fail_safe
BIT7: DP-V1_Enable
(Default value: 1100 0000
B
)
9 DPV1 Status2 DPV1 status 2 (See EN50170.)
BIT0: Check_Cfg_Mode
BIT1: reserved
BIT7-2: 0 (fixed)
(Default value: 0000 0001
B
)
10 DPV1 Status3 DPV1 status 3 (See EN50170.) 0 (fixed)