3-6 DP-V1 Service
3-30
- PROFIBUS DP Compatible Network Unit DL-PD1 User's Manual (IG) -
Executing Communication
IG series index (Slot 1 to 4)
Attribute R: Read; W: Write; R/W: Read/Write; C: Motion command
The data types are DINT (32-bit signed integer).
Index
(DEC)
Function name
Description
Data
type
Attribute
Default
value
Value
0 Group0 Entry count DINT R 20
1 Zero shift execution request DINT C 1
2
Zero shift reset execution request
DINT C 1
3 Reset request DINT C 1
4 Reserved for system
5 Initial reset request DINT C 1
6
System parameter set request
DINT C 1
7 to 9 Reserved for system
10
Standard waveform
registration request
DINT C 1
11 to 13 Reserved for system
14 Tolerance tuning request DINT C 1
15
Two-point
tuning
(HIGH, 1st point)
determination action request
DINT C 1
16
Two-point
tuning
(HIGH, 2nd
point) determination action request
DINT C 1
17
Two-point
tuning
(LOW, 1st point)
determination action request
DINT C 1
18
Two-point
tuning
(LOW, 2nd point)
determination action request
DINT C 1
19
Calibration SET1
determination action request
DINT C 1
20
Calibration SET2
determination action request
DINT C 1
21 to 31 Reserved for system
32 Group1 Entry Count DINT R 29
33 Sensor amplifier error state *1 DINT R
Bit0: Overcurrent Error (ErC)
Bit1: EEPROM Error (ErE)
Bit2: Head Error (ErH)
Bit3:
Light transmitter/emitter
reverse connection error
Bit4: Light receiver EEPROM
error
Bit5: Light receiver error
Bit6: Light transmitter error
Bit7: Light transmitter laser
error
Bit8: Model mismatch error
Bit9: Head error (standard
waveform registration)
Bit10:
Standard waveform
registration error 1, 2, 3, 4
Bit11: Communication error
Bit12: Expansion error
Bit13: Calculation error
34 to 35 Reserved for system
Commentaires sur ces manuels